Range Hood Size Guide: Width, Depth and CFM
Match the hood to the cooktop: at least as wide and ideally a size wider, 18 to 22 inches deep, with enough CFM for the way you cook.
A range hood should be at least as wide as the cooktop, ideally about 3 inches wider on each side, and 18 to 22 inches deep. For airflow, plan about 100 CFM for every 10,000 BTU of gas burners, or about 100 CFM per foot of cooktop width for electric.
Above 400 CFM, many building codes require make-up air, so the biggest fan is not always the best choice.
Width: at least the cooktop width; a 30-inch range takes a 30 to 36-inch hood. Depth: 18 to 22 inches. CFM: 100 per 10,000 BTU for gas; for electric, HVI recommends 100 per foot of width on a wall and 150 on an island. Over 400 CFM: check the make-up air rules.
A width chart, CFM rules with worked examples, depth and height, make-up air and six hoods from 24 to 48 inches are below.
Product links go to Amazon. As an Amazon Associate, Kitchen Guide 101 earns from qualifying purchases.
Six Range Hoods by Width and CFM
All 6 side by side. Tap any name to see it on Amazon.
| Range hood | Widths | Max CFM | Venting | Best for | Price |
|---|---|---|---|---|---|
| Broan-NuTone 36-Inch Convertible Range Hood (350 CFM, 1.5 Sones, Energy Star) | 24, 30, 36, 42 in | 350 | Ducted or ductless (HPF30) | Quiet, under 400 CFM | $$$ |
| Hauslane Chef Series UC-PS18 30″ Under-Cabinet Range Hood | 30, 36 in | Under 350 (capped) | Ducted only | Skipping make-up air | $$ |
| Cosmo COS-QS75 30″ Haven Collection Ducted Under-Cabinet Range Hood | 30, 36, 48 in | 500 | Ducted (CFK5 kit for ductless) | Wide ranges | $$ |
| ZLINE 523-36 Convertible Under-Cabinet Range Hood | 36, 48 in | 480 to 700 | Ducted or ductless (RK filters) | Pro-style ranges | $$$ |
| VIKIO HOME 30″ Ducted Under-Cabinet Range Hood, 980 CFM (RC11-30) | 30, 36, 42 in | 980 | Ducted (round or rectangular) | Wok cooking and big gas ranges | $$ |
| IKTCH 30″ Range Hood Insert, 900 CFM (B01) | 30, 36 in inserts | 900 | Ducted or ductless | Custom hood shells | $$ |
Details are as stated on each Amazon listing at time of writing and can change. Price tiers: $ lowest in this group · $$ middle · $$$ highest.
6 Range Hoods From 24 to 48 Inches, 350 to 980 CFM
Picked to cover every common width and airflow level, from quiet hoods under the 400 CFM line to a 980 CFM fan.
Broan-NuTone 36-Inch Convertible Range Hood (350 CFM, 1.5 Sones, Energy Star)
One listing covers 24, 30, 36 and 42 inches, so it can match the cooktop or go a size up. At 350 CFM it stays under the 400 CFM make-up air line, and Broan rates it at 1.5 sones on its working speed.
For ductless use, add the HPF30 charcoal filter.
- Four widths
- Very quiet
- Under 400 CFM
- Two speeds only
- Charcoal filter extra
Hauslane Chef Series UC-PS18 30″ Under-Cabinet Range Hood
Hauslane caps the airflow under 350 CFM, which the maker says saves the cost of a make-up air unit. Six speeds and a dual motor still handle everyday frying and searing.
It comes in 30 and 36-inch widths and fits 6-inch round or 3¼ x 10-inch ducts.
- Stays under 400 CFM
- Two widths
- Fits three duct types
- Ducted only
- Capped airflow limits very heavy cooking
Cosmo COS-QS75 30″ Haven Collection Ducted Under-Cabinet Range Hood
Cosmo sells it in 30, 36 and 48-inch widths, so it can match a wide range. 500 CFM covers about 50,000 BTU of gas burners by the 100 CFM per 10,000 BTU rule.
It vents through a 7.5-inch round duct and is over the 400 CFM line.
- Three widths
- Strong airflow
- Quiet on low
- Over 400 CFM
- Needs a 7.5-inch duct
ZLINE 523-36 Convertible Under-Cabinet Range Hood
A pro-style hood in brushed 430 stainless with a four-speed fan from 480 to 700 CFM. Even the lowest speed is 480 CFM, so plan for make-up air.
It connects to round ductwork on top, or converts with ZLINE’s RK charcoal filters, sold separately.
- Pro-style look
- Lifetime motor warranty
- Convertible
- Over 400 CFM on every speed
- Few ratings on the listing
VIKIO HOME 30″ Ducted Under-Cabinet Range Hood, 980 CFM (RC11-30)
The most airflow here: up to 980 CFM from a DC motor. VIKIO says it refreshes the air in a 180-square-foot kitchen every 90 seconds.
Round and rectangular duct adapters are both included. At 980 CFM, plan for make-up air.
- Most airflow here
- Gesture and touch control
- Both duct adapters included
- Well over 400 CFM
- No published noise rating
IKTCH 30″ Range Hood Insert, 900 CFM (B01)
An insert sits inside a custom hood shell or cabinet. Buy it by the inside width of the shell: a 30 to 33-inch opening takes a 30-inch insert, and 36 to 39 inches takes a 36-inch one.
This IKTCH moves up to 900 CFM, from 40 to 65 dB, with gesture and touch controls.
- Strong airflow
- Two sizes
- Ducted or ductless
- Needs a hood shell
- Over 400 CFM
Range Hood Width by Cooktop Size
| Cooktop | Hood width | Notes |
|---|---|---|
| 24 in | 24 to 30 in | A 30-inch hood catches more |
| 30 in | 30 to 36 in | The most common pairing |
| 36 in | 36 to 42 in | A 42-inch hood catches more |
| 48 in | 48 in or larger | Pro-style ranges |
| Island cooktop | Same width, up to 6 in wider | Canopy about 24 to 26 in deep |
Whirlpool suggests letting the hood run about 3 inches past each side of the cooking surface. Building a custom hood? Inserts are sized by the shell’s inside width; see the range hood insert size chart.
How Much CFM Do You Need?
| Cooktop | Rule | Examples |
|---|---|---|
| Gas | 100 CFM per 10,000 BTU | 40,000 BTU: 400 CFM; 60,000 BTU: 600 CFM |
| Electric or induction, wall hood | 100 CFM per foot of width | 30 in: 250 CFM; 36 in: 300 CFM |
| Electric or induction, island hood | 150 CFM per foot of width | 36 in: 450 CFM |
| Everyday home cooking | 200 to 300 CFM | Most standard ranges |
For gas, add up the BTU of every burner first. HVI notes that the duct’s width, bends and length all affect how well air leaves the house, so a long run with elbows needs a little more fan. For fan sizing in general, see kitchen exhaust fan size.
Depth, Height and Coverage
Depth
18 to 22 inches covers the burners on most ranges.
Island canopy
The cooktop width or up to 6 inches wider, about 24 to 26 inches deep.
Height
20 to 24 inches above electric, 24 to 30 above gas, never more than 36.
Slim hoods
Ultra-slim models are about 4 inches thick for shallow cabinets.
Cabinets
The cabinet above the range sets the room you have. See upper cabinet sizes.
The range
Check its exact width first. See standard stove dimensions.
Full height guide: how high to mount a range hood.
Make-Up Air: The 400 CFM Line
Under the International Residential Code (section M1503.4 in the 2024 edition), a kitchen hood that can move more than 400 CFM needs make-up air: a way for outside air to replace what the hood pulls out. The trigger is the hood’s maximum rating, not the speed you usually run. Local codes vary, so check before you buy.
| Hood here | Max CFM | Against the 400 CFM line |
|---|---|---|
| Broan-NuTone 36-Inch | 350 | Under |
| Hauslane UC-PS18 | Under 350 | Under |
| Cosmo COS-QS75 | 500 | Over: check local code |
| ZLINE 523-36 | 700 | Over: check local code |
| IKTCH Insert | 900 | Over: check local code |
| VIKIO HOME RC11-30 | 980 | Over: check local code |
Unsure about venting at all? Compare ducted vs ductless range hoods.
How to Size a Range Hood in 5 Steps
Five steps.
Measure the cooktop
Side to side. The hood should be at least that wide.
Go a size up if you can
A 36-inch hood over a 30-inch range catches more smoke.
Work out the CFM
Gas: total BTU divided by 100. Electric: 100 CFM per foot of width on a wall.
Check the 400 CFM line
Over 400 CFM may need make-up air.
Match the duct
Use the duct size the hood calls for; long runs and elbows cut airflow.
More range hood guides: ducted under-cabinet hoods, ductless under-cabinet hoods, convertible range hoods explained and the best convertible range hoods.
Range Hood Size FAQs
What size range hood do I need for a 30-inch stove?▼
30 to 36 inches wide. A 36-inch hood over a 30-inch range catches more smoke.
Should a range hood be wider than the stove?▼
Ideally, yes. Whirlpool suggests about 3 inches past each side; at the least, match the cooktop width.
How many CFM do I need for a gas stove?▼
About 100 CFM per 10,000 BTU. A 40,000 BTU cooktop needs about 400 CFM, and 60,000 BTU about 600.
How many CFM do I need for an electric stove?▼
About 100 CFM per foot of width for a wall hood: about 250 CFM for 30 inches and 300 for 36 inches, per HVI.
How many CFM does an island range hood need?▼
About 150 CFM per foot of cooktop width, per HVI: about 450 CFM over a 36-inch cooktop.
Is 600 CFM too much for a home kitchen?▼
Not for a big gas range, but it is over 400 CFM, so many codes require make-up air.
How deep should a range hood be?▼
18 to 22 inches for most hoods, enough to cover the burners.
Do I need make-up air for my range hood?▼
If it can move more than 400 CFM, often yes. The International Residential Code requires it, and local codes vary.
The Bottom Line
- Width: at least the cooktop, ideally a size up. The Broan-NuTone 36-Inch comes in 24 to 42 inches.
- CFM: 100 per 10,000 BTU for gas, 100 per foot of width for electric. To stay under 400 CFM, the Hauslane UC-PS18 is capped below 350.
- Heavy cooking: the VIKIO HOME RC11-30 moves 980 CFM; plan for make-up air.
Size the width to the cooktop, the CFM to your burners, and check the 400 CFM line.